Brand
Cyber Power
Description
Cyber Power UPS OLS Tower 10000VA/10000W PF1
SKU
OLS10KEA
General
UPS Topology Online Double Conversion
Energy Saving Technology ECO Mode Eciency > 98%
Active PFC Compatibility Yes
Parallel Expansion (Max. Units) 4 (Optional)
Input
Generator Compatibility Yes
Nominal Input Voltage (Vac) 230
Input Voltage Range (Vac) 110 ~ 300
Input Frequency (Hz) 50 ± 10, 60 ± 10
Input Frequency Detection Auto-sensing
Rated Input Current (A) 49.5
Input Power Factor 0.99
Input PFC Function Yes
Input Connector Type Hardwire Terminal Block
Output
Capacity (VA) 10000
Capacity (Watts) 10000
On Battery Waveform Pure Sine Wave
On Battery Voltage(s) (Vac) 200 ± 1%, 208 ± 1%, 220 ± 1%, 230 ± 1%, 240 ± 1%
Output Voltage Setting Configurable
On Battery Frequency (Hz) 50 ± 0.5%, 60 ± 0.5%
Output Frequency Setting Configurable
Power Factor 1
Overload Protection Internal Current Limiting, Circuit Breaker, Fuse
Overload Protection (Line Mode) 105~130% Load for 10 sec, >130% Load for 1.5 sec
Overload Protection (Battery Mode) 105~130% Load for 10 sec, >130% Load for 1.5 sec
Overload Protection (Bypass Mode) 110~120% Load for 30 min, 120~130% Load for 2 min, 130~150% Load for 15 sec, >150% Load Immediately
Harmonic Distortion (Linear Load) THD<1.5%
Harmonic Distortion (Non-linear Load) THD<3%
Outlet(s) Total 1
Outlet Type Hardwire Terminal Block x 1
Typical Transfer Time (ms) 0
Battery
Runtime at Half Load (min) 7.8
Runtime at Full Load (min) 1.8
Typical Recharge Time (Hours) 4
Adjustable Charging Current (A) 1 ~ 4
Smart Battery Management (SBM) Yes
Automatic Battery Self-test During Power-on Yes
Battery Type
Compatible Extended Battery Module (EBM) Yes
Max. EBM Quantity (pcs) 10
Surge Protection & Filtering
Surge Suppression (Joules) 1335
EMI/RFI Filtration Yes
Management & Communications
LCD Panel Yes
LCD Types Color LCD
HID Compliant USB Port(s) 1
Serial Port RS232
Dry Contact (with Relay) Yes
Emergency Power O (EPO) Port Yes
Power Management Software PowerPanel Business (Recommended)
SNMP/HTTP Remote Monitoring Yes - with optional RMCARD205
PowerPanel Cloud Service Yes - 90 Days Free Trial with PowerPanel Personal/Business
Physical
Form Factor Tower
Environmental
Operating Temperature (°C) 0 ~ 40
Operating Relative Humidity (Non-condensing) (%) 0 ~ 95
Certifications
Certifications* CE
RoHS Yes
Dimensions (WxHxD) (mm.)
270 x 520 x 460
Warranty
2 Years onsite
*ผิด ตก ยกเว้น Errors and omissions excepted (E&OE)*
หมายเหตุ จำนวนสินค้าในสต๊อกมีการเปลี่ยนแปลงทุกวัน กรุณาตรวจสอบจำนวนสินค้า และราคาก่อนการสั่งซื้อนะคะ